A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device
executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset.
CVSS v4.0 Metrics
Exploitability
Attack VectorLocal
ComplexityLow
RequirementsPresent
PrivilegesNone
User InteractionActive
Threat
Exploit MaturityPoC
Vulnerable System
ConfidentialityNone
IntegrityNone
AvailabilityHigh
Subsequent System
ConfidentialityNone
IntegrityNone
AvailabilityNone
Supplemental
SafetyNegligible
AutomatableYes
RecoveryAutomatic
Value DensityConcentrated
UrgencyMedium
Change Log
| Date | Source | Changes | Score |
|---|
| 2026-07-21 | cve.org | initial, patch: Unavailable | 4.4 |
Affected Software
| Vendor | Product | Version |
|---|
| Siemens | LOGO! 12/24RCE | 0 |
| Siemens | LOGO! 12/24RCEo | 0 |
| Siemens | LOGO! 230RCE | 0 |
| Siemens | LOGO! 230RCEo | 0 |
| Siemens | LOGO! 24CE | 0 |
| Siemens | LOGO! 24CEo | 0 |
| Siemens | LOGO! 24RCE | 0 |
| Siemens | LOGO! 24RCEo | 0 |
| siemens | logo\!_8_bm_firmware | All versions |
| Siemens | SIPLUS LOGO! 12/24RCE | 0 |
| Siemens | SIPLUS LOGO! 12/24RCEo | 0 |
| Siemens | SIPLUS LOGO! 230RCE | 0 |
| Siemens | SIPLUS LOGO! 230RCEo | 0 |
| Siemens | SIPLUS LOGO! 24CE | 0 |
| Siemens | SIPLUS LOGO! 24CEo | 0 |
| Siemens | SIPLUS LOGO! 24RCE | 0 |
| Siemens | SIPLUS LOGO! 24RCEo | 0 |
Published: 2021-03-15