A vulnerability has been identified in SIMARIS configuration (All versions < V4.0.1). During installation to default target folder, incorrect permissions are configured for the application folder and subfolders which could allow an attacker to gain persistence or potentially escalate privileges should a user with elevated credentials log onto the machine.
An official patch is available. Apply the patch as soon as possible.
CVSS v4.0 Metrics
Exploitability
Attack VectorLocal
ComplexityLow
RequirementsPresent
PrivilegesLow
User InteractionNone
Threat
Exploit MaturityUnreported
Vulnerable System
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
Subsequent System
ConfidentialityNone
IntegrityNone
AvailabilityNone
Supplemental
SafetyNegligible
AutomatableYes
RecoveryAutomatic
Value DensityConcentrated
UrgencyMedium
Patch StatusOfficial Patch
Change Log
| Date | Source | Changes | Score |
|---|
| 2026-07-21 | nvd | AV: P→L, AC: H→L, PR: H→L, UI: A→N, VC: N→H, VI: N→H, VA: N→H | 0.0 → 4.4 |
| 2026-07-21 | nvd | patch: Unavailable→Official Patch | 0.0 → 0.0 |
| 2026-07-21 | cve.org | initial, patch: Unavailable | 0.0 |
Affected Software
| Vendor | Product | Version |
|---|
| Siemens | SIMARIS configuration | < 4.0.1 |
| siemens | simaris_configuration | < 4.0.1 |
Published: 2021-02-09